OM20-P0120.HH.YIN Distance sensors

We are authorized dealer in india

Baumer Performance Sensor Features:

  • Automatic adjustment of exposure time for precise measurements on changing materials
  • High immunity to ambient light for reliable measurements regardless of ambient conditions
  • Point beam shape for precise measurements
  • Adjustable filters for particularly stable measurement results


General Data:


Type: Distance Measuring

Measuring Distance (Sd): 16 … 120 mm

Measuring Range (Mr): 104 mm

Adjustment: Teach-in Button / IO-Link

Power On Indication: LED Green

Output Indicator: LED Yellow

Repeat Accuracy: 1 … 13 µm

Linearity Error: ± 0.1% Mr (16 … 70 mm), ± 0.16% Mr (16 … 120 mm)

Beam Type: Point

Temperature Drift: 0.04% Sde/K


Light Source:


Light Source: Pulsed Red Laser Diode

Wavelength: 660 nm

Laser Class: 1

Maximum Pulse Power: 2 mW

Pulse Duration: 0.001 … 0.5 ms

Pulse Period: 0.2 … 3.4 ms


Electrical Data:


Response Delay: 0.4 ms

Measuring Frequency: 5000 Hz

Voltage Supply Range (+Vs): 12 … 28 VDC

Current Consumption Max. (No Load): 50 mA

Output Circuit: Analog and Digital

Output Signal: 4 … 20 mA / 2 … 10 mA

Load Resistance: < (+Vs – 9 V) / 0.02 A

Output Current: < 100 mA

Short Circuit Protection: Yes

Reverse Polarity Protection: Yes, Vs to GND


Communication Interface:


Interface: IO-Link V1.1

IO-Link Port Type: Class A

Baud Rate: 230.4 kBaud (COM 3)

Cycle Time: ≥ 1 ms

Process Data Length: 48 Bit

Process Data Structure: Smart Sensor Profile – DMS PDI48.INT32_INT8


Mechanical Data:


Width / Diameter: 13 mm

Height / Length: 37 mm

Depth: 34.5 mm

Type: Rectangular, Front View

Housing Material: Die-cast Zinc

Front (Optics): Glass

Connection Types: Connector M8 4 Pin

Weight: 41 g


Ambient Conditions:


Ambient Light Immunity: < 100 kLux

Protection Class: IP 67

Operating Temperature: -10 … +50 °C

Storage Temperature: -20 … +60 °C

Vibration (Sinusoidal): IEC 60068-2-6:2008 (1 mm p-p at f = 10 – 55 Hz, duration 5 min per axis, 30 min endurance at f = 55 Hz per axis)

Shock (Semi-sinusoidal): IEC 60068-2-27:2009 (30 g / 11 ms, 6 jolts per axis and direction)