HOG 10 Incremental encoders Baumer
We are authorized dealer in india

TTL output driver supports cable lengths up to 550 m
HTL output driver accommodates cable lengths up to 350 m
Remarkable resistance to shock and vibrations
Features a hybrid bearing for an extended service life
Equipped with a large terminal box, rotatable by 180° or axial terminal cover
Electrical Ratings - Technical Data:
Voltage Supply: 9…30 VDC, 5 VDC ±5%
Consumption without Load: ≤100 mA
Pulses per Revolution: 300 … 5000
Phase Shift: 90° ±20°
Duty Cycle: 40…60%
Reference Signal: Zero pulse, width 90°
Sensing Method: Optical
Output Frequency: ≤120 kHz, ≤300 kHz (on request)
Output Signals: K1, K2, K0 + inverted, Error output (option EMS)
Output Stages: HTL-P (power linedriver), TTL/RS422
Shaft Insulation: Suitable up to 2.8 kV
Transmission Length:
≤350 m at 100 kHz (HTL-P)
≤550 m at 100 kHz (TTL)
Interference Immunity: EN 61000-6-2
Emitted Interference: EN 61000-6-3
Approval: CE, UL approval / E217823
Mechanical Design - Technical Data:
Size (Flange): ø105 mm
Shaft Type: ø12…20 mm (blind hollow shaft), ø17 mm (cone shaft 1:10)
Admitted Shaft Load: ≤450 N axial, ≤600 N radial
Protection EN 60529: IP 66
Operating Speed: ≤6000 rpm (mechanical)
Operating Torque (typ.): 6 Ncm
Rotor Moment of Inertia: 340 gcm²
Material:
Housing: Aluminium die-cast
Shaft: Stainless steel
Operating Temperature: -40…+100 °C, -25…+100 °C (>3072 pulses), -50…+100 °C (optional)
Resistance: IEC 60068-2-6, Vibration 20 g, 10-2000 Hz, IEC 60068-2-27, Shock 300 g, 6 ms
Corrosion Protection: IEC 60068-2-52 Salt mist for ambient conditions C4 according to ISO 12944-2
Explosion Protection:
II 3 G Ex ec IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust) (only with option ATEX)
Connection: Terminal box, Terminal cover, 2x terminal box (with option M)
Weight Approx.: 1.6 kg, 1.8 kg (with option M)